Altronix MAXIMAL7 Access Power Controller, Single AL1024ULXB, 16 Fused Outputs

$697.64

    • 115VAC 60Hz, 4.2 amp input
    • 24VDC outputs
    • Maximum output current: 24VDC @ 9.4 amp
    • Sixteen (16) auxiliary power outputs (unswitched) (outputs are rated 2.5 amp)
    • Filtered and electronically regulated outputs (built-in power supply)
SKU: MAXIMAL7 Category:
 

Description

This unit distributes and switches power to access control systems and accessories. It converts a 115VAC 60Hz input into sixteen (16) independently controlled 24VDC fuse protected outputs. These power outputs can be converted to dry form “C” contacts. Outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. The unit will route power to a variety of access control hardware devices including: Mag Locks, Electric Strikes, Magnetic Door Holders, etc. Outputs will operate in both Fail-Safe and/or Fail-Secure modes. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the sixteen (16) outputs.

Features

  • 115VAC 60Hz, 4.2 amp input
  • 24VDC outputs
  • Maximum output current: 24VDC @ 9.4 amp
  • Sixteen (16) auxiliary power outputs (unswitched) (outputs are rated 2.5 amp)
  • Filtered and electronically regulated outputs (built-in power supply)
  • Thermal and short circuit protection with auto reset
  • Power Supply input fuse rated @ 10 amp/250V
  • ACM8 boards main fuse is rated at 10 amp. Output fuses are rated @ 3.5 amp
  • Alarm output relay indicates that FACP input is triggered (form “C” contact rated @ 1 amp 28VDC)
  • AC fail supervision (form “C” contact)
  • Low battery and battery presence supervision (form “C” contact)
  • Built-in charger for sealed lead acid or gel type batteries
  • Maximum charge current 3.6 amp
  • Automatic switch over to stand-by battery when AC fails
  • Zero voltage drop when unit switches over to battery backup (AC failure condition)
  • Red LEDs indicate outputs are triggered (relays energized)
  • Green LED indicates FACP disconnect is triggered
  • AC input and DC output LED indicators

Additional information

UPC

upc

782239947607

Manufacturer