Altronix T2CVK3310 10-Door Altronix/CDVI Access and Power Integration Kit

$774.95

SKUT2CVK3310
Categories,

Altronix T2CVK3310 kit consists of Trove2 enclosure, TCV2 CDVI/Altronix backplane with two (2) 12 or 24VDC @ 6A power supply/chargers, and two (2) PTC protected five (5) output Power Distribution Modules with Fire Alarm Interface. This kit also accommodate various combinations of CDVI Atrium A22K/A22NB/ADH10 boards for up to ten (10) doors in a single enclosure. Trove simplifies board layout and wire management, reduces installation time and labor costs.

Features

AL600ULXB Power Supply/Charger

Input

  • Voltage: 115VAC, 60Hz, 3.5A max
  • Fusing: 5A / 250V

Outputs

  • Voltage: 12VDC or 24VDC selectable
  • Current: 6A @ 12VDC or 24VDC continuous max
  • Other: Overvoltage protection. Filtered and regulated

Battery Backup

  • Capacity: 7AH/12VDC (Up to 2 within enclosure) 40AH/65AH (requires separate enclosure)
  • Type: Sealed lead acid or gel type
  • Failover: Upon AC loss, instantaneous

Supervision

  • AC Failure: Form “C” contacts
  • Battery: Form “C” contacts

Indicators LED

  • Input: 115VAC is present
  • DC Output: Powered
  • Battery: Discharged or not connected

Two (2) MOM5 Power Distribution Modules with Fire Alarm Interface

Input

  • Voltage: 12VDC or 24VDC from power supply

Output

  • Five (5) individual Class 2 Rated PTC protected power-limited outputs (auto-resettable)
  • Voltage: 12VDC or 24VDC
  • Current: 2.5A continuous supply current. Current limit is 2A per output
  • Other: Short circuit and thermal overload protection. Filtered and regulated

Fire Alarm Interface

  • Fire Alarm Panel or Access Control System trigger inputs N.O. or N.C. supervised trigger input and polarity reversal trigger input

Supervision

  • Power Failure: Form “C” contact rated 1A 28VDC/115VAC
  • Trigger: Form “C” contact rated 1A 28VDC/115VAC

Indicators (LED)

  • Input: Power is present
  • Input Trigger: On
  • Outputs (Individual LEDs): Output fail

Environmental

Temperature

  • Operating: 0° C to 49° C (32° F to 120° F)
  • Storage: – 20° C to 70° C ( – 4° F to 158° F)

Relative Humidity

  • Relative Humidity 85% +/- 5%

BTU/Hr (approx.):

  • 12VDC: 74 BTU/Hr
  • 24VDC: 148 BTU/Hr
  • 12VDC and 24VDC: 111 BTU/Hr

Additional information

Weight 59.7 lbs
Netsuite ID

Reviews

There are no reviews yet.

Be the first to review “Altronix T2CVK3310 10-Door Altronix/CDVI Access and Power Integration Kit”

Your email address will not be published. Required fields are marked *

Reviews

There are no reviews yet.

Be the first to review “Altronix T2CVK3310 10-Door Altronix/CDVI Access and Power Integration Kit”

Your email address will not be published. Required fields are marked *