Altronix T2CVK710 10-Door Altronix/CDVI Access and Power Integration Kit

$847.50

SKUT2CVK710
Categories,

Altronix T2CVK710 kit consists of Trove2 enclosure, TCV2 CDVI/Altronix backplane with one (1) 24VDC @ 10A power supply/charger, one (1) 8-output fused access power controller, one (1) 4-output fused access power controller and one (1) 8-output fused power distribution module. This kit also accommodate various combinations of CDVI Atrium A22K/A22NB/ADH10 boards for up to ten (10) doors in a single enclosure. Trove simplifies board layout and wire management, reduces installation time and labor costs.

Features

AL1024ULXB2 Power Supply/Charger

Input

  • Voltage: 115VAC 60Hz, 4.2A max
  • Main Fuse: 5A / 250V

Outputs

  • Voltage: 24VDC
  • Current: 10A @ 24VDC continuous max
  • Other: Overvoltage protection. Filtered and regulated

Battery Backup

  • Capacity: 12AH /12VDC (2 within enclosure), 40 AH / 65 AH (requires separate enclosure)
  • Type: Sealed lead acid or gel type
  • Failover: Upon AC loss, instantaneous

Supervision

  • AC Failure: Form “C” contacts
  • Battery: Form “C” contacts

Indicators LED

  • Input: 115VAC is present
  • DC Output: Powered
  • Battery: Discharged or not connected

ACM8 Access Power Controller

Input

  • Voltage: 24VDC from AL1024ULXB2
  • Main Fuse: 10A / 32V

Outputs

  • Voltage: 24VDC
  • Eight (8) independently controlled fused outputs:
  • a) Fail-Safe and/or Fail-Secure power outputs. Form “C” Relays rated 28VAC or VDC @ 2.5A
  • b) Auxiliary power outputs (unswitched)
  • c) Any combination of the above
  • Eight (8) auxiliary power outputs (unswitched)
  • Output Fuses: 3.5A/250V

Indicators (LED)

  • Red LEDs: Outputs are triggered (relays energized)
  • Green LED: FACP disconnect is triggered

ACM4 Access Power Controller

Input

  • Voltage: 24VDC from AL1024ULXB2
  • Main Fuse: 10A/32V

Outputs

  • Voltage: 24VDC
  • Four (4) independently controlled 2.5A outputs:
  • a) Four (4) Fail-Safe and/or Fail-Secure power outputs
  • b) Four (4) dry form “C” 5A rated relay outputs
  • c) Any combination of the above
  • Four (4) auxiliary power outputs (unswitched)
  • Output Fuses: 3A / 32V

Indicators (LED)

  • Red LEDs: Outputs are triggered (relays energized)
  • Green LED: FACP disconnect is triggered

PD8UL Power Distribution Module

Input

  • Voltage: 24VDC from AL1024ULXB2

Outputs

  • Voltage: 24VDC
  • Eight (8) fuse protected outputs
  • 3.5A per output max
  • Output Fuses: 3.5A/250V

Indicators (LED)

  • Green LED: DC Output

Environmental

Temperature

  • Operating: 0° C to 49° C (32° F to 120° F)
  • Storage: – 20° C to 70° C ( – 4° F to 158° F)

Relative Humidity

  • Relative Humidity 85% +/- 5%

BTU/Hr (approx.):

  • 131 BTU/Hr

Additional information

Weight 59.7 lbs
Netsuite ID

Reviews

There are no reviews yet.

Be the first to review “Altronix T2CVK710 10-Door Altronix/CDVI Access and Power Integration Kit”