Altronix T2HWK712V 12-Door Altronix/Honeywell Access and Power Integration Kit

$1,281.49

SKUT2HWK712V
Categories,

Altronix T2HWK712DV kit consists of Trove2 enclosure, THW2 Honeywell/Altronix backplane, THWD2 Honeywell door backplane with one (1) 24VDC @ 10A power supply/charger, one (1) 8-output PTC access power controller, one (1) 4-output PTC access power controller, one (1) voltage regulator and one (1) 8-output PTC dual input power distribution module.THW2 backplane also accommodates up to three (3) Honeywell 4200 Series or WIN-PAK Series boards and up to one (1) Honeywell PW7K1ICE, PW7K1R1E boards for up to twelve (12) doors in a single enclosure. THWD2 accommodates additional one (1) Honeywell PRO22MX8/PW5K1MX8 and up to six (6) Honeywell 4200 Series or WIN-PAK Series. Trove simplifies board layout and wire management, reduces installation time and labor costs.

Features

AL1024XB2V Power Supply/Charger

Input

  • Voltage: 220VAC (working range 198VAC-256VAC), 50/60Hz, 2.5A
  • Fusing: 5A / 250V

Outputs

  • Voltage: 24VDC
  • Current: 10A @ 24VDC continuous max
  • Other: Overvoltage protection. Filtered and regulated

Battery Backup

  • Capacity: 12AH /12VDC (2 within enclosure), 40 AH / 65 AH (requires separate enclosure)
  • Type: Sealed lead acid or gel type
  • Failover: Upon AC loss, instantaneous

Supervision

  • AC Failure: Form “C” contacts
  • Battery: Form “C” contacts

Indicators LED

  • Input: 220VAC is present
  • DC Output: Powered
  • Battery: Discharged or not connected

PDS8 Dual Input Power Distribution Module

Input

  • Voltage: 12VDC from VR6 and 24VDC from AL1024XB2V
  • Input Fuse: 10A / 32V

Outputs

  • Voltage: 12VDC and/or 24VDC
  • Any of the eight (8) power outputs are selectable to follow power Input 1 or Input 2
  • Individual outputs may be set to OFF position for servicing

Outputs Ratings

  • Fuses: 3A/32V

Indicators (LED)

  • DC Output: Eight (8) individual output LEDs
  • Green: 12VDC
  • Red: 24VDC

VR6 Voltage Regulator

Input

  • Voltage: 24VDC from AL1024XB2V

Output

  • Voltage: 12VDC
  • Current: 6A continuous
  • Other: Surge suppression

Indicators LED

  • Input: 24VDC is present
  • Output: Powered

ACM8 Access Power Controller

Input

  • Voltage: 24VDC from AL1024XB2V
  • Input Fuse: 10A / 250V

Outputs

  • Voltage: 24VDC
  • Eight (8) independently controlled fused outputs:
  • a) Fail-Safe and/or Fail-Secure power outputs. Form “C” Relays rated 28VAC or VDC @ 2.5A
  • b) Auxiliary power outputs (unswitched)
  • c) Any combination of the above
  • Output Fuses: 3.5A/250V

Indicators (LED’s)

  • Red LEDs: Outputs are triggered (relays energized)
  • Green LED: FACP disconnect is triggered

ACM4 Access Power Controller

Input

  • Voltage: 24VDC from AL1024XB2V
  • Input Fuse: 10A /32V

Outputs

  • Voltage: 24VDC
  • Four (4) independently controlled fused outputs:
  • a) Fail-Safe and/or Fail-Secure power outputs
  • Form “C” Relays rated 28VAC or VDC @ 2.5A
  • b) Auxiliary power outputs (unswitched)
  • c) Any combination of the above
  • Output Fuses: 3A / 32V

Indicators (LED)

  • Red LEDs: Outputs are triggered (relays energized)
  • Green LED: FACP disconnect is triggered

Environmental

Temperature

  • Operating: 0° C to 49° C (32° F to 120° F)
  • Storage: – 20° C to 70° C ( – 4° F to 158° F)

Relative Humidity

  • Relative Humidity 85% +/- 5%

BTU/Hr (approx.):

  • 128 BTU/Hr

Additional information

Weight 59.3 lbs
Netsuite ID

Reviews

There are no reviews yet.

Be the first to review “Altronix T2HWK712V 12-Door Altronix/Honeywell Access and Power Integration Kit”