Altronix T2MK3F8ADQ 8-Door Altronix/Mercury Access and Power Integration Kit

$1,106.13

SKUT2MK3F8ADQ
Categories,

Altronix T2MK3F8ADQ kit consists of Trove2 enclosure and TM2 Mercury/Altronix backplane with 24VDC @ 6A power supply/charger, 12VDC voltage regulator, eight (8) PTC protected output dual input/output network access control module and eight (8) PTC protected dual input/output power distribution module. This kit also accommodates various combinations of Mercury/Lenel* boards for up to eight (8) doors in a single enclosure. Trove simplifies board layout and wire management, reduces installation time and labor costs.*Also compatible with these authentic Mercury partners:AccessNsite, Avigilon, BadgePass, BluBox, Feenics, Genetec, Identicard, IMRON, Johnson Controls, Kastle, Keri Systems, Lenel/S2, LockState, Maxxess, Midpoint Security, NLSS, Open Options, Panasonic Video Insight, Quintron, RS2, Schneider Electric, Vanderbilt

Features

eFlow6NB Power Supply/Charger

Input

  • Voltage: 120VAC, 60Hz. 3.5A
  • Input Fuse: 5A / 250V

Output

  • Voltage: 24VDC
  • Current: 6A continuous
  • Auxiliary: 1A (unswitched)
  • Other: Overvoltage protection. Filtered and regulated

Battery Backup

  • Capacity: 7AH / 12VDC (Up to 2 within enclosure). 40 AH / 65 AH (requires separate enclosure)
  • Type: Sealed lead acid or gel type
  • Fuse Rating: 10A/32V
  • Failover: Upon AC loss, instantaneous

Supervision

  • AC Failure: Form “C” contacts
  • Battery: Form “C” contacts
  • Low DC Power Shutdown: Shuts down DC output terminals if battery voltage drops below 70-75% for 24V units. (depending on the power supply). Prevents deep battery discharge

Indicators LED

  • Input: 120VAC is present
  • DC Output: Powered
  • Battery: Discharged or not connected

LINQ8ACMCB Networked Access Power Controller

Input

  • Two (2) Independent Low Voltage Inputs:
  • – Input 1: 24 VDC from eFlow6NB power supply
  • – Input 2: 12 VDC from VR6 voltage regulator
  • Input PTC: 9A

Outputs

  • PTC protected outputs
  • Any of the eight (8) PTC protected power outputs are selectable to follow power Input 1 or Input 2
  • Individual outputs may be set to OFF position for servicing

Output PTCs:

  • 2.5A

Programming Features:

IEight (8) Programmable Outputs:

  • – Fail-safe, fail-secure or auxiliary outputs
  • – Input controlled or manually controlled through software
  • – High (over) and low (under) voltage and current monitoring by output
  • – Multiple outputs may be programmed to be triggered by a single input
  • – Battery back-up by output

Eight (8) Programmable Trigger Inputs:

  • – Normally open (NO), Normally colsed (NC) or Open collector sink inputs
  • – Wet Input (5VDC – 24VDC) with 10k resistor
  • – Any combination of the above

Other Programmable Trigger Inputs:

  • – Monitor power supply(ies) input for voltage and currect limits (high/low)
  • – Input and output current calibration, Programmable timer events
  • – Programmable user levels, Enable or disable alerts by type
  • – Programmable alert reporting delay

Indicators (LED)

  • Green AC LED: indicates AC trouble condition
  • Green BAT LED: indicates battery trouble condition
  • Green FACP LED: indicates FACP disconnect is triggered
  • Flashing Blue Heartbeat LED: indicates network connection
  • Individual OUT1 – OUT8 Red LEDs: indicate outputs are triggered
  • Individual Voltage LEDs: indicate 12VDC (Green) or 24VDC (Red)

VR6 Voltage Regulator

Input

  • Voltage: 24VDC from eFlow6NB

Output

  • Voltage: 12VDC
  • Current: 6A continuous
  • Other: Surge suppression

Indicators LED

  • Input: 24VDC is present
  • Output: Powered

PDS8CB Dual Input Power Distribution Module

Input

  • Voltage: 12VDC from VR6 and 24VDC from eFlow6NB
  • Input PTC Rating: 9A

Outputs

  • Voltage: 12VDC and/or 24VDC
  • Any of the eight (8) power outputs are selectable to follow power Input 1 or Input 2
  • Individual outputs may be set to OFF position for servicing

Outputs Ratings

  • PTCs: 2.5A

Indicators (LED)

  • DC Output: Eight (8) individual output LEDs
  • Green: 12VDC
  • Red: 24VDC

Environmental

Temperature

  • Operating: 0° C to 49° C (32° F to 120° F)
  • Storage: – 20° C to 70° C ( – 4° F to 158° F)

Relative Humidity

  • Relative Humidity 85% +/- 5%

BTU/Hr (approx.):

  • 145 BTU/Hr

Additional information

Weight 43.85 lbs
Netsuite ID

Reviews

There are no reviews yet.

Be the first to review “Altronix T2MK3F8ADQ 8-Door Altronix/Mercury Access and Power Integration Kit”