Altronix T3CVK7720 kit consists of Trove3 enclosure, TCV3 CDVI/Altronix backplane with two (2) 24VDC @ 10A power supply/chargers, two (2) 8-output fused access power controllers, one (1) 4-output fused access power controller and one (1) 8-output fused power distribution module. Also featured is a rocker switch bracket with two (2) rocker switches. This kit also accommodate various combinations of CDVI Atrium A22K/A22NB/ADH10 boards for up to twenty (20) doors in a single enclosure. Trove simplifies board layout and wire management, reduces installation time and labor costs.
Features
Two (2) AL1024ULXB2 Power Supply/Chargers
Input
- Voltage: 115VAC 60Hz, 4.2A max
- Main Fuse: 5A / 250V
Outputs
- Voltage: 24VDC
- Current: 10A @ 24VDC continuous max
- Other: Overvoltage protection. Filtered and regulated
Battery Backup
- Capacity: 12AH /12VDC (2 within enclosure), 40 AH / 65 AH (requires separate enclosure)
- Type: Sealed lead acid or gel type
- Failover: Upon AC loss, instantaneous
Supervision
- AC Failure: Form “C” contacts
- Battery: Form “C” contacts
Indicators LED
- Input: 115VAC is present
- DC Output: Powered
- Battery: Discharged or not connected
Two (2) ACM8 Access Power Controllers
Input
- Voltage: 24VDC from AL1024ULXB2
- Input Fuse: 10A / 250V
Outputs
- Voltage: 24VDC
- Eight (8) independently controlled fused outputs:
- a) Fail-Safe and/or Fail-Secure power outputs. Form “C” Relays rated 28VAC or VDC @ 2.5A
- b) Auxiliary power outputs (unswitched)
- c) Any combination of the above
- Output Fuses: 3.5A / 250V
Indicators (LED)
- Red LEDs: Outputs are triggered (relays energized)
- Green LED: FACP disconnect is triggered
ACM4 Access Power Controller
Input
- Voltage: 24VDC from AL1024ULXB2
- Input Fuse: 10A /32V
Outputs
- Voltage: 24VDC
- Four (4) independently controlled 2.5A outputs:
- a) Four (4) Fail-Safe and/or Fail-Secure power outputs
- b) Four (4) dry form “C” 5A rated relay outputs
- c) Any combination of the above
- Four (4) auxiliary power outputs (unswitched)
- Output Fuses: 3A / 32V
Indicators (LED)
- Red LEDs: Outputs are triggered (relays energized)
- Green LED: FACP disconnect is triggered
PD8UL Power Distribution Module
Input
- Voltage: 24VDC from AL1024ULXB2
Outputs
- Voltage: 24VDC
- Eight (8) fuse protected outputs
- 3.5A per output max
- Output Fuses: 3.5A/250V
Indicators (LED)
- Green LED: DC Output
Environmental
Temperature
- Operating: 0° C to 49° C (32° F to 120° F)
- Storage: – 20° C to 70° C ( – 4° F to 158° F)
Relative Humidity
- Relative Humidity 85% +/- 5%
BTU/Hr (approx.):
- 263 BTU/Hr