Altronix T3M7724LXK1D 24-Door Altronix/Mercury Access and Power Integration Kit

$3,680.82

SKUT3M7724LXK1D
Categories,

Altronix T3M7724LXK1D is a 24-door access and power integration kit which includes Altronix power and sub-assemblies along with factory installed wire management and wire assemblies that are pre-configured with terminal blocks for Mercury hardware. This unit provides ample power and dual voltage outputs to support Mercury platform controllers and locking devices. The T3M7724LXK1D accommodates up to one (1) Intelligent Dual Reader Controller and eleven (11) Dual Reader Interface Modules. Trove Plus simplifies field installations and provides reliable, robust critical power and control for the most demanding applications.

Features

Two (2) AL1024ULXB2 Power Supply/Chargers

Input

  • Voltage: 115VAC, 60Hz, 4.2A max
  • Main Fuse: 5A / 250V

Outputs

  • Voltage: 24VDC
  • Current: 10A @ 24VDC continuous max
  • Other: Filtered and regulated

Battery Backup

  • Capacity: 12AH /12VDC (2 within enclosure), 40 AH / 65 AH (requires separate enclosure)
  • Type: Sealed lead acid or gel type
  • Failover: Upon AC loss, instantaneous

Supervision

  • AC Failure: Form “C” contacts
  • Battery: Form “C” contacts

Indicators LED

  • Input: 115VAC is present
  • DC Output: Powered
  • Battery: Discharged or not connected

Two (2) ACMS12CB Dual Input Access Power Controllers

Input

  • Voltage: 24VDC from AL1024ULXB2, 12VDC from VR6
  • Input PTCs: 9A

Outputs

  • Voltage: 12VDC and/or 24VDC
  • Twelve (12) independently controlled PTC outputs:
  • a) Fail-Safe and/or Fail-Secure power outputs
  • Form “C” Relays rated 28VAC or VDC @ 2.5A
  • b) Auxiliary power outputs (unswitched)
  • c) Any combination of the above

Outputs Ratings

  • PTCs: 2.5A

Indicators (LED’s)

  • Red LEDs: Outputs are triggered (relays energized)
  • Green LED: FACP disconnect is triggered

Two (2) VR6 Voltage Regulators

Input

  • Voltage: 24VDC from AL1024ULXB2

Output

  • Voltage: 12VDC
  • Current: 6A continuous
  • Other: Surge suppression

Indicators LED

  • Input: 24VDC is present
  • Output: Powered

Two (2) PDS16CB Dual Input Power Distribution Modules

Input

  • Voltage: 12VDC & 24VDC from ACMS12CB
  • Input PTCs: 9A

Outputs

  • Voltage: 12VDC and/or 24VDC
  • Any of the sixteen (16) power outputs are selectable to follow power Input 1 or Input 2
  • Individual outputs may be set to OFF position for servicing
  • Output PTCs: 2.5A

Indicators (LED)

  • DC Output: Sixteen (16) individual output LEDs
  • Green: 12VDC
  • Red: 24VDC

Environmental

Temperature

  • Operating: 0° C to 49° C (32° F to 120° F)
  • Storage: – 20° C to 70° C ( – 4° F to 158° F)

Relative Humidity

  • Relative Humidity 85% +/- 5%

BTU/Hr (approx.):

  • 289 BTU/Hr

Additional information

Weight 85.6 lbs
Netsuite ID

Reviews

There are no reviews yet.

Be the first to review “Altronix T3M7724LXK1D 24-Door Altronix/Mercury Access and Power Integration Kit”

Your email address will not be published. Required fields are marked *

Reviews

There are no reviews yet.

Be the first to review “Altronix T3M7724LXK1D 24-Door Altronix/Mercury Access and Power Integration Kit”

Your email address will not be published. Required fields are marked *