The Altronix MAXIMAL75K3 Access Power Controller is designed to efficiently manage and distribute power to access control systems while providing advanced features for enhanced security. With its ability to convert 115VAC 60Hz input into sixteen independently controlled 12VDC and 24VDC outputs, this power controller ensures reliable operation for various access control hardware. Its robust construction and user-friendly features make it an essential component for any security system.
Altronix MAXIMAL75K3 Access Controller Features
- Input Power: 115VAC 60Hz, 7.0A input provides reliable performance for demanding applications.
- Trigger Inputs: Sixteen (16) Access Control System trigger inputs allow for versatile integration with various security devices.
- Output Voltage: 12VDC and 24VDC outputs ensure compatibility with a wide range of access control systems.
- Independently Controlled Outputs: Sixteen (16) independently controlled outputs offer flexibility in managing multiple devices.
- Fire Alarm Disconnect: Easily selectable latching or non-latching fire alarm disconnect for any or all outputs enhances safety measures.
- Alarm Relay Output: Indicates FACP input is triggered, ensuring real-time monitoring of security status.
- AC Fail Supervision: Provides form “C” contacts for AC failure notifications, ensuring system reliability.
- Notification Trigger: Selectable trigger duration (30 seconds or 6 hours) for tailored alerting based on user needs.
- Battery Supervision: Low battery and battery presence supervision through form “C” contacts for maintaining system integrity.
- Built-in Charger: Supports sealed lead acid or gel-type batteries for convenient power backup.
- Automatic Battery Switch Over: Seamlessly switches to standby battery during AC failure without voltage drop.
- LED Indicators: Red LEDs indicate triggered outputs, while green LED indicates FACP disconnect status for user awareness.
- Input/Output Indicators: AC input and DC output LED indicators for easy status monitoring.
Detailed Specifications for Altronix MAXIMAL75K3
| Input Voltage | 115VAC 60Hz |
| Input Current | 7.0A |
| Number of Outputs | 16 |
| Output Voltage Options | 12VDC / 24VDC |
| Relay Outputs | Form “C” contacts rated at 1A 28VDC |
| Fire Alarm Disconnect | Individually selectable for each output |
| Battery Type | Sealed lead acid or gel-type |
| LED Indicators | Red for triggered outputs, green for FACP disconnect |
| Notification Trigger Duration | 30 seconds (factory set) or 6 hours |
| AC Fail Supervision | Form “C” contacts |
| Automatic Switch Over | Zero voltage drop during AC failure |
| Dimensions | BC800 Enclosure |