Altronix T1M1LCK1 4-Door Altronix/Mercury Access and Power Integration Kit

$740.64

SKUT1M1LCK1
Categories,

Altronix T1M1LCK1 is a 4-door access and power integration kit which includes Altronix power and sub-assemblies along with factory installed wire management and wire assemblies that are pre-configured with terminal blocks for Mercury* hardware. This unit provides ample power and dual voltage outputs to support Mercury platform controllers and locking devices. The T1M1LCK1 accommodates one (1) Intelligent Dual Reader Controller and one (1) Dual Reader Interface Modules. Trove Plus simplifies field installations and provides reliable, robust critical power and control for the most demanding applications.*Also compatible with these authentic Mercury partners:AccessNsite, Avigilon, BadgePass, BluBox, Feenics, Genetec, Identicard, IMRON, Johnson Controls, Kastle, Keri Systems, LockState, Maxxess, Midpoint Security, NLSS, Open Options, Panasonic i-PRO MonitorCast, Quintron, RS2, S2 Security, Schneider Electric, Vanderbilt.

Features

AL400ULXB2 Power Supply/Charger

Input

  • Voltage: 115VAC, 60Hz, 3.5A max
  • Input Fuse: 5A / 250V

Outputs

  • Voltage: 12VDC or 24VDC selectable
  • Current: 4A @ 12VDC or 3A @ 24VDC continuous max
  • Other: Overvoltage protection. Filtered and regulated

Battery Backup

  • Capacity: 7AH/12VDC (Up to 2 within enclosure); 40 AH/65 AH (requires separate enclosure)
  • Type: Sealed lead acid or gel type
  • Fuse Rating: 15A/32V
  • Failover: Upon AC loss, instantaneous

Supervision

  • AC Failure: Form “C” contacts
  • Battery: Form “C” contacts

Indicators LED

  • Input: 115VAC is present
  • DC Output: Powered
  • Battery: Discharged or not connected

PDS8 Dual Input Power Distribution Module

Input

  • Voltage: 12VDC from VR6 and 24VDC from AL400ULXB2
  • Input Fuse: 10A / 32V

Outputs

  • Voltage: 12VDC and/or 24VDC
  • Any of the eight (8) power outputs are selectable to follow power Input 1 or Input 2
  • Individual outputs may be set to OFF position for servicing

Outputs Ratings

  • Fuses: 3A/32V

Indicators (LED’s)

  • DC Output: Eight (8) individual output LEDs
  • Green: 12VDC
  • Red: 24VDC

VR6 Voltage Regulator

Input

  • Voltage: 24VDC from AL400ULXB2

Output

  • Voltage: 12VDC
  • Current: 6A continuous
  • Other: Surge suppression

Indicators LED

  • Input: 24VDC is present
  • Output: Powered

ACM4 Access Power Controller

Input

  • Voltage: 24VDC from AL400ULXB2
  • Input Fuse: 10A / 32V

Outputs

  • Voltage: 24VDC
  • Four (4) independently controlled 2.5A outputs:
  • a) Four (4) Fail-Safe and/or Fail-Secure power outputs
  • b) Four (4) dry form “C” 5A rated relay outputs
  • c) Any combination of the above
  • Four (4) auxiliary power outputs (unswitched)

Outputs Ratings

  • Fuses: 3A / 32VDC

Indicators (LED)

  • Red LEDs: Outputs are triggered (relays energized)
  • Green LED: FACP disconnect is triggered

Environmental

Temperature

  • Operating: 0° C to 49° C (32° F to 120° F)
  • Storage: – 20° C to 70° C ( – 4° F to 158° F)

Relative Humidity

  • Relative Humidity 85% +/- 5%

BTU/Hr (approx.):

  • 90 BTU/Hr

Additional information

Weight 22 lbs
Netsuite ID

Reviews

There are no reviews yet.

Be the first to review “Altronix T1M1LCK1 4-Door Altronix/Mercury Access and Power Integration Kit”

Your email address will not be published. Required fields are marked *

Reviews

There are no reviews yet.

Be the first to review “Altronix T1M1LCK1 4-Door Altronix/Mercury Access and Power Integration Kit”

Your email address will not be published. Required fields are marked *