Altronix T1M1LCK1 is a 4-door access and power integration kit which includes Altronix power and sub-assemblies along with factory installed wire management and wire assemblies that are pre-configured with terminal blocks for Mercury* hardware. This unit provides ample power and dual voltage outputs to support Mercury platform controllers and locking devices. The T1M1LCK1 accommodates one (1) Intelligent Dual Reader Controller and one (1) Dual Reader Interface Modules. Trove Plus simplifies field installations and provides reliable, robust critical power and control for the most demanding applications.*Also compatible with these authentic Mercury partners:AccessNsite, Avigilon, BadgePass, BluBox, Feenics, Genetec, Identicard, IMRON, Johnson Controls, Kastle, Keri Systems, LockState, Maxxess, Midpoint Security, NLSS, Open Options, Panasonic i-PRO MonitorCast, Quintron, RS2, S2 Security, Schneider Electric, Vanderbilt.
Features
AL400ULXB2 Power Supply/Charger
Input
- Voltage: 115VAC, 60Hz, 3.5A max
- Input Fuse: 5A / 250V
Outputs
- Voltage: 12VDC or 24VDC selectable
- Current: 4A @ 12VDC or 3A @ 24VDC continuous max
- Other: Overvoltage protection. Filtered and regulated
Battery Backup
- Capacity: 7AH/12VDC (Up to 2 within enclosure); 40 AH/65 AH (requires separate enclosure)
- Type: Sealed lead acid or gel type
- Fuse Rating: 15A/32V
- Failover: Upon AC loss, instantaneous
Supervision
- AC Failure: Form “C” contacts
- Battery: Form “C” contacts
Indicators LED
- Input: 115VAC is present
- DC Output: Powered
- Battery: Discharged or not connected
PDS8 Dual Input Power Distribution Module
Input
- Voltage: 12VDC from VR6 and 24VDC from AL400ULXB2
- Input Fuse: 10A / 32V
Outputs
- Voltage: 12VDC and/or 24VDC
- Any of the eight (8) power outputs are selectable to follow power Input 1 or Input 2
- Individual outputs may be set to OFF position for servicing
Outputs Ratings
- Fuses: 3A/32V
Indicators (LED’s)
- DC Output: Eight (8) individual output LEDs
- Green: 12VDC
- Red: 24VDC
VR6 Voltage Regulator
Input
- Voltage: 24VDC from AL400ULXB2
Output
- Voltage: 12VDC
- Current: 6A continuous
- Other: Surge suppression
Indicators LED
- Input: 24VDC is present
- Output: Powered
ACM4 Access Power Controller
Input
- Voltage: 24VDC from AL400ULXB2
- Input Fuse: 10A / 32V
Outputs
- Voltage: 24VDC
- Four (4) independently controlled 2.5A outputs:
- a) Four (4) Fail-Safe and/or Fail-Secure power outputs
- b) Four (4) dry form “C” 5A rated relay outputs
- c) Any combination of the above
- Four (4) auxiliary power outputs (unswitched)
Outputs Ratings
- Fuses: 3A / 32VDC
Indicators (LED)
- Red LEDs: Outputs are triggered (relays energized)
- Green LED: FACP disconnect is triggered
Environmental
Temperature
- Operating: 0° C to 49° C (32° F to 120° F)
- Storage: – 20° C to 70° C ( – 4° F to 158° F)
Relative Humidity
- Relative Humidity 85% +/- 5%
BTU/Hr (approx.):
- 90 BTU/Hr



















Reviews