Altronix T1PHK14SD kit consists of Trove1 enclosure, TC1 Openpath/Altronix backplane with one (1) 12VDC 4A or 24VDC @ 3A power supply/charger, one (1) PTC access power controller, one dual input power distribution module and one (1) voltage regulator. This kit also accommodates up to one (1) Openpath Core, Elevator Board, 4-Port or 8-Port modules for up to eight (8) doors in a single enclosure. Trove simplifies board layout and wire management, reduces installation time and labor costs.
Features
AL400ULXB2 Power Supply/Charger
Input
- Voltage: 115VAC, 60Hz, 3.5A max
- Input Fuse: 5A / 250V
Outputs
- Voltage: 12VDC or 24VDC selectable
- Current: 4A @ 12VDC or 3A @ 24VDC continuous max
- Other: Overvoltage protection. Filtered and regulated
Battery Backup
- Capacity: 7AH/12VDC (Up to 2 within enclosure); 40 AH/65 AH (requires separate enclosure)
- Type: Sealed lead acid or gel type
- Fuse Rating: 15A/32V
- Failover: Upon AC loss, instantaneous
Supervision
- AC Failure: Form “C” contacts
- Battery: Form “C” contacts
Indicators LED
- Input: 115VAC is present
- DC Output: Powered
- Battery: Discharged or not connected
PDS8CB Dual Input Power Distribution Module
Input
- Voltage: 12VDC from VR6 and 24VDC from AL400ULXB2
- Input PTC: 10A
Outputs
- Voltage: 12VDC and/or 24VDC
- Any of the eight (8) power outputs are selectable to follow power Input 1 or Input 2
- Individual outputs may be set to OFF position for servicing
Outputs Ratings
- Fuses 3A/32V
Indicators (LED)
- DC Output: Eight (8) individual output LEDs
- Green: 12VDC
- Red: 24VDC
VR6 Voltage Regulator
Input
- Voltage: 24VDC from AL400ULXB2
Output
- Voltage: 12VDC
- Current: 6A continuous
- Other: Surge suppression
Indicators LED
- Input: 24VDC is present
- Output: Powered
ACM4CB Access Power Controller
Input
- 24VDC from AL400ULXB2
- Input Fuse: 5A/250V
Outputs
- Voltage: 24VDC
- Four (4) independently controlled 2.5A outputs:
- a) Four (4) Fail-Safe and/or Fail-Secure power outputs
- Four (4) auxiliary power outputs (unswitched)
Outputs Ratings
- PTCs: 2.5A
Indicators (LED)
- Red LEDs: Outputs are triggered (relays energized)
- Green LED: FACP disconnect is triggered
Environmental
Temperature
- Operating: 0° C to 49° C (32° F to 120° F)
- Storage: – 20° C to 70° C ( – 4° F to 158° F)
Relative Humidity
- Relative Humidity 85% +/- 5%
BTU/Hr (approx.):
- 12VDC: 40 BTU/Hr
- 24VDC: 77 BTU/Hr