Altronix T2MK74 4-Door Altronix/Mercury Access and Power Integration Kit

$773.54

-
+

Altronix T2MK74 kit consists of Trove2 enclosure and TM2 Altronix & Mercury backplane with 24VDC @ 10A power supply/charger, four (4) fuse protected output access control module and eight (8) fuse protected output power distribution module. This kit also accommodates various combinations of Mercury* boards for up to four (4) doors in a single enclosure. Trove simplifies board layout and wire management, reduces installation time and labor costs.*Also compatible with these authentic Mercury partners:AccessNsite, Avigilon, BadgePass, BluBox, Feenics, Genetec, Identicard, IMRON, Johnson Controls, Kastle, Keri Systems, Lenel/S2, LockState, Maxxess, Midpoint Security, NLSS, Open Options, Panasonic Video Insight, Quintron, RS2, Schneider Electric, Vanderbilt

Features

AL1024ULXB2 Power Supply/Charger

Input

  • Voltage: 115VAC 60Hz, 4.2A max
  • Main Fuse: 5A / 250V

Outputs

  • Voltage: 24VDC
  • Current: 10A @ 24VDC continuous max
  • Other: Overvoltage protection. Filtered and regulated

Battery Backup

  • Capacity: 12AH /12VDC (2 within enclosure), 40 AH / 65 AH (requires separate enclosure)
  • Type: Sealed lead acid or gel type
  • Failover: Upon AC loss, instantaneous

Supervision

  • AC Failure: Form “C” contacts
  • Battery: Form “C” contacts

Indicators LED

  • Input: 115VAC is present
  • DC Output: Powered
  • Battery: Discharged or not connected

ACM4 Access Power Controller

Input

  • Voltage: 24VDC from AL1024ULXB2
  • Input Fuse: 10A / 32V

Outputs

  • Voltage: 24VDC
  • Four (4) independently controlled 2.5A outputs:
  • a) Four (4) Fail-Safe and/or Fail-Secure power outputs
  • b) Four (4) dry form “C” 5A rated relay outputs
  • c) Any combination of the above
  • Four (4) auxiliary power outputs (unswitched)

Outputs Ratings

  • Fuses: 3A/32V

Indicators (LED’s)

  • Red LEDs: Outputs are triggered (relays energized)
  • Green LED: FACP disconnect is triggered

PD8UL Power Distribution Module

Input

  • Voltage: 24VDC from AL1024ULXB2

Outputs

  • Voltage: 24VDC
  • Fuses: 3.5A/250V

Indicators LED

  • Green LED: DC Output

Environmental

Temperature

  • Operating: 0° C to 49° C (32° F to 120° F)
  • Storage: – 20° C to 70° C ( – 4° F to 158° F)

Relative Humidity

  • Relative Humidity 85% +/- 5%

BTU/Hr (approx.):

  • 145 BTU/Hr

Additional information

Weight 43.000000 lbs

Reviews

There are no reviews yet.

Be the first to review “Altronix T2MK74 4-Door Altronix/Mercury Access and Power Integration Kit”

Your email address will not be published. Required fields are marked *

Reviews

There are no reviews yet.

Be the first to review “Altronix T2MK74 4-Door Altronix/Mercury Access and Power Integration Kit”

Your email address will not be published. Required fields are marked *