Altronix T2MK7516 16-Door Altronix/Mercury Access and Power Integration Kit – Trove2M2 with AL1024ULXB2, AL1012ULXB, 2-ACM8, PD16W

$1,070.95

-
+
Brand86522
SKUT2MK7516

Altronix T2MK7516 kit consists of Trove2 enclosure, TM2 Altronix & Mercury backplane and TMV2 door backplane with 24VDC @ 10A and 12VDC @ 10A power supply/chargers, sixteen (16) fuse protected output power distribution module and two eight (8) fuse protected output access control modules. This kit also accommodates various combinations of Mercury* boards for up to sixteen (16) doors in a single enclosure. Trove simplifies board layout and wire management, reduces installation time and labor costs.

*Also compatible with these authentic Mercury partners: AccessNsite, Avigilon, BadgePass, BluBox, Feenics, Genetec, Identicard, IMRON, Johnson Controls, Kastle, Keri Systems, Lenel/S2, LockState, Maxxess, Midpoint Security, NLSS, Open Options, Panasonic Video Insight, Quintron, RS2, S2 Security, Schneider Electric, Vanderbilt.

Features

AL1024ULXB2 Power Supply/Charger – 1

  • Input
  • Voltage: 115VAC, 60Hz, 4.2A max
  • Main Fuse: 5A / 250V
  • Output
  • Voltage: 24VDC
  • Current: 10A @ 24VDC continuous max
  • Other: Overvoltage protection. Filtered and regulated

AL1012ULXB Power Supply/Charger – 2

  • Input
  • Voltage: 115VAC, 60Hz, 2.6A max
  • Main Fuse: 5A / 250V
  • Output
  • Voltage: 12VDC
  • Current: 10A @ 12VDC continuous max
  • Other: Overvoltage protection. Filtered and regulated
  • Both Power Supplies
  • Battery Backup (not included)
  • Capacity: 12AH /12VDC (2 within enclosure); 40 AH / 65 AH (requires separate enclosure)
  • Type: Sealed lead acid or gel type
  • Failover: Upon AC loss, instantaneous
  • Supervision
  • AC Failure: Form “C” contacts
  • Battery: Form “C” contacts
  • Indicators LED
  • Input: 115VAC is present
  • DC Output: Powered
  • Battery: Discharged or not connected

Two (2) ACM8 Access Power Controllers

  • Input
  • Voltage: 24VDC from Al1024ULXB
  • Input Fuse: 10A / 250V
  • Outputs
  • Voltage: 24VDC
  • Eight (8) 24VDC independently controlled fused outputs:
    a) Fail-Safe and/or Fail-Secure power outputs. Form “C” Relays rated 28VAC or VDC @ 2.5A.
    b) Auxiliary power outputs (unswitched).
    c) Any combination of the above
  • Output Fuses: 3.5A/250V
  • Indicators (LED)
  • Red LEDs: Outputs are triggered (relays energized)
  • Green LED: FACP disconnect is triggered

PD16W Power Distribution Module

  • Input
  • Voltage: 12VDC from AL1012ULXB
  • Output
  • Voltage: 12VDC
  • Fuses: 3.5A/250V
  • Indicators LED
  • Green LED: DC Output

Environmental

  • Temperature
  • Operating: 0° C to 49° C (32° F to 120° F)
  • Storage: – 20° C to 70° C ( – 4° F to 158° F)
  • Relative Humidity
  • Relative Humidity 85% +/- 5%
  • BTU/Hr (approx.):
  • 217 BTU/Hr

Additional information

Weight 54.350000 lbs

Reviews

There are no reviews yet.

Be the first to review “Altronix T2MK7516 16-Door Altronix/Mercury Access and Power Integration Kit – Trove2M2 with AL1024ULXB2, AL1012ULXB, 2-ACM8, PD16W”

Your email address will not be published. Required fields are marked *

Reviews

There are no reviews yet.

Be the first to review “Altronix T2MK7516 16-Door Altronix/Mercury Access and Power Integration Kit – Trove2M2 with AL1024ULXB2, AL1012ULXB, 2-ACM8, PD16W”

Your email address will not be published. Required fields are marked *