Altronix T2PXK78D kit consists of Trove2 enclosure, TPX2 Paxton/Altronix backplane with one (1) 24VDC @ 10A power supply/charger, one (1) PTC protected eight (8) output access power controller and one (1) PTC protected eight (8) dual output power distribution module and one (1) voltage regulator. This kit also accommodates Paxton Net2 Plus boards for up to eight (8) doors or Paxton10 for up to six (6) doors in a single enclosure. Trove simplifies board layout and wire management, reduces installation time and labor costs.
Features
AL1024ULXB2 Power Supply/Charger
Input
- Voltage: 115VAC, 60Hz, 4.2A max
- Main Fuse: 5A / 250V
Outputs
- Voltage: 24VDC
- Current: 10A @ 24VDC continuous max
- Other: Overvoltage protection. Filtered and regulated
Battery Backup
- Capacity: 12AH /12VDC (2 within enclosure), 40 AH / 65 AH (requires separate enclosure)
- Type: Sealed lead acid or gel type
- Failover: Upon AC loss, instantaneous
Supervision
- AC Failure: Form “C” contacts
- Battery: Form “C” contacts
Indicators LED
- Input: 115VAC is present
- DC Output: Powered
- Battery: Discharged or not connected
ACM8CB Access Power Controller
Input
- Voltage: 24VDC from AL1024ULXB2
- Main Fuse: 10A / 250V
Outputs
- Voltage: 24VDC
- Eight (8) 24VDC independently controlled PTC outputs:
- a) Fail-Safe and/or Fail-Secure power outputs. Form “C” Relays rated 28VAC or VDC @ 2.5A
- b) Auxiliary power outputs (unswitched)
- c) Any combination of the above
- Output PTCs: 2.5A
Indicators (LED)
- Red LEDs: Outputs are triggered (relays energized)
- Green LED: FACP disconnect is triggered
VR6 Voltage Regulator
Input
- Voltage: 24VDC from AL1024XB2
Output
- Voltage: 12VDC
- Current: 6A continuous
- Other: Surge suppression
Indicators LED
- Input: 24VDC is present
- Output: Powered
PDS8CB Dual Input Power Distribution Module
Input
- Voltage: 12VDC from VR6 and 24VDC from AL1024ULXB2
- Input PTC: 9A
Outputs
- Voltage: 12VDC and/or 24VDC
- Any of the eight (8) power outputs are selectable to follow power Input 1 or Input 2
- Individual outputs may be set to OFF position for servicing
Outputs Ratings
- PTCs are rated 2.5A
Environmental
Temperature
- Operating: 0° C to 49° C (32° F to 120° F)
- Storage: – 20° C to 70° C ( – 4° F to 158° F)
Relative Humidity
- Relative Humidity 85% +/- 5%
BTU/Hr (approx.):
- 145 BTU/Hr



















Reviews
There are no reviews yet.