Altronix T2RM78S 8-Door Altronix/Mercury Access & Power Integration Kit

$1,809.23

-
+

Altronix T2RM78S rack kit consists of Trove2M2R enclosure/backplane with one (1) 24VDC @ 10A power supply/charger, one (1) dual input eight (8) fuse protected output access control module, one (1) voltage regulator and one (1) dual input eight (8) fuse protected output power distribution module. This kit also accommodates various combinations of Mercury* boards for up to eight (8) doors in a single enclosure. Trove simplifies board layout and wire management, reduces installation time and labor costs.*Also compatible with these authentic Mercury partners:AccessNsite, Avigilon, BadgePass, BluBox, Feenics, Genetec, Identicard, IMRON, Johnson Controls, Kastle, Keri Systems, Lenel/S2, LockState, Maxxess, Midpoint Security, NLSS, Open Options, Panasonic Video Insight, Quintron, RS2, Schneider Electric, Vanderbilt

Features

AL1024ULXB2 Power Supply/Charger

Input

  • Voltage: 115VAC, 60Hz, 4.2A max
  • Main Fuse: 5A / 250V

Output

  • Voltage: 24VDC
  • Current: 10A @ 24VDC continuous max
  • Other: Overvoltage protection. Filtered and regulated

Battery Backup

  • Type: Sealed lead acid or gel type
  • Failover: Upon AC loss, instantaneous

Supervision

  • AC Failure: Form “C” contacts
  • Battery: Form “C” contacts

Indicators LED

  • Input: 115VAC is present
  • DC Output: Powered
  • Battery: Discharged or not connected

ACMS8 Dual Input Access Power Controller

Input

  • Voltage: 24VDC from AL1024ULXB2 and 12VDC from VR6
  • Input Fuse: 15A / 32V

Outputs

  • Voltage: 12 or 24VDC individually selectable
  • Eight (8) selectable 12VDC – 24VDC independently controlled outputs or eight (8) indepently controlled Form “C” relay outputs:
  • a) Fail-Safe and/or Fail-Secure power outputs
  • b) Form “C” Relays. 28VAC or VDC @ 2.5A Rated
  • c) Auxiliary power outputs (unswitched)
  • d) Any combination of the above
  • Any of the eight (8) fuse protected power outputs are selectable to follow power Input 1 or Input 2
  • Individual outputs may be set to OFF position for servicing

Outputs Ratings

  • Fuses: 3A/32V

Indicators (LED’s)

  • Red LEDs: Outputs are triggered (relays energized)
  • Blue LED: FACP disconnect is triggered
  • Individual voltage LEDs:
  • Green: 12VDC
  • Red: 24VDC

VR6 Voltage Regulator

Input

  • Voltage: 24VDC from AL1024ULXB2

Output

  • Voltage: 12VDC
  • Current: 6A continuous
  • Other: Surge suppression

Indicators LED

  • Input: 24VDC is present
  • Output: Powered

PDS8 Dual Input Power Distribution Module

Input

  • Voltage: 24VDC from AL1024ULXB2 and 12VDC from VR6
  • Input Fuse: 10A / 32V

Outputs

  • Voltage: 12VDC and/or 24VDC
  • Any of the eight (8) power outputs are selectable to follow power Input 1 or Input 2
  • Individual outputs may be set to OFF position for servicing

Outputs Ratings

  • Fuses: 3A/32V

Indicators (LED’s)

  • DC Output: Eight (8) individual output LEDs
  • Green: 12VDC
  • Red: 24VDC

Environmental

Temperature

  • Operating: 0° C to 49° C (32° F to 120° F)
  • Storage: – 20° C to 70° C ( – 4° F to 158° F)

Relative Humidity

  • Relative Humidity 85% +/- 5%

BTU/Hr. (approx.):

  • 123 BTU/Hr

Additional information

Weight 45.5 lbs

Reviews

There are no reviews yet.

Be the first to review “Altronix T2RM78S 8-Door Altronix/Mercury Access & Power Integration Kit”

Your email address will not be published. Required fields are marked *

Reviews

There are no reviews yet.

Be the first to review “Altronix T2RM78S 8-Door Altronix/Mercury Access & Power Integration Kit”

Your email address will not be published. Required fields are marked *