Altronix T2RM78SDQ rack kit consists of Trove2M2R enclosure/backplane with one (1) 24VDC @ 10A power supply/charger, one (1) dual input networked eight (8) PTC protected output access control module, one (1) voltage regulator and one (1) dual input eight (8) PTC protected output power distribution module. This kit also accommodates various combinations of Mercury* boards for up to eight (8) doors in a single enclosure. Trove simplifies board layout and wire management, reduces installation time and labor costs.*Also compatible with these authentic Mercury partners:AccessNsite, Avigilon, BadgePass, BluBox, Feenics, Genetec, Identicard, IMRON, Johnson Controls, Kastle, Keri Systems, Lenel/S2, LockState, Maxxess, Midpoint Security, NLSS, Open Options, Panasonic Video Insight, Quintron, RS2, Schneider Electric, Vanderbilt
Features
AL1024ULXB2 Power Supply/Charger
Input
- Voltage: 115VAC, 60Hz, 4.2A max
- Main Fuse: 5A / 250V
Output
- Voltage: 24VDC
- Current: 10A @ 24VDC continuous max
- Other: Overvoltage protection. Filtered and regulated
Battery Backup
- Type: Sealed lead acid or gel type
- Failover: Upon AC loss, instantaneous
Supervision
- AC Failure: Form “C” contacts
- Battery: Form “C” contacts
Indicators LED
- Input: 115VAC is present
- DC Output: Powered
- Battery: Discharged or not connected
VR6 Voltage Regulator
Input
- Voltage: 24VDC from AL1024ULXB2
Output
- Voltage: 12VDC
- Current: 6A continuous
- Other: Surge suppression
Indicators LED
- Input: 24VDC is present
- Output: Powered
PDS8CB Dual Input Power Distribution Module
Input
- Voltage: 12VDC from VR6 and 24VDC from AL1024ULXB2
- Input PTC: 9A
Outputs
- Voltage: 12VDC and/or 24VDC
- Any of the eight (8) power outputs are selectable to follow power Input 1 or Input 2
- Individual outputs may be set to OFF position for servicing
Outputs Ratings
- PTCs are rated 2.5A
Indicators (LED)
- DC Output: Eight (8) individual output LEDs
- Green: 12VDC
- Red: 24VDC
LINQ8ACMCB Networked Access Power Controller
Input
- Two (2) Independent Low Voltage Inputs:
- – Input 1: 24 VDC from AL1024ULXB2 power supply
- – Input 2: 12 VDC from VR6 voltage regulator
- Input PTC: 9A
Outputs
- PTC protected outputs
- Any of the eight (8) power outputs are selectable to follow power Input 1 or Input 2
- Individual outputs may be set to OFF position for servicing
Output PTCs:
- 2.5A
Programming Features:
IEight (8) Programmable Outputs:
- – Fail-safe, fail-secure or auxiliary outputs
- – Input controlled or manually controlled through software
- – High (over) and low (under) voltage and current monitoring by output
- – Multiple outputs may be programmed to be triggered by a single input
- – Battery back-up by output
Eight (8) Programmable Trigger Inputs:
- – Normally open (NO), Normally colsed (NC) or Open collector sink inputs
- – Wet Input (5VDC – 24VDC) with 10k resistor
- – Any combination of the above
Other Programmable Trigger Inputs:
- – Monitor power supply(ies) input for voltage and currect limits (high/low)
- – Input and output current calibration, Programmable timer events
- – Programmable user levels, Enable or disable alerts by type
- – Programmable alert reporting delay
Indicators (LED)
- Green AC LED: indicates AC trouble condition
- Green BAT LED: indicates battery trouble condition
- Green FACP LED: indicates FACP disconnect is triggered
- Flashing Blue Heartbeat LED: indicates network connection
- Individual OUT1 – OUT8 Red LEDs: indicate outputs are triggered
- Individual Voltage LEDs: indicate 12VDC (Green) or 24VDC (Red)
Environmental
Temperature
- Operating: 0° C to 49° C (32° F to 120° F)
- Storage: – 20° C to 70° C ( – 4° F to 158° F)
Relative Humidity
- Relative Humidity 85% +/- 5%
BTU/Hr (approx.):
- 123 BTU/Hr



















Reviews
There are no reviews yet.