Altronix T3HWK7516D kit consists of Trove3 enclosure, THW3 Honeywell/Altronix backplane and THWD2 Honeywell/Altronix door backplane with one (1) 24VDC @ 10A and one (1) 12VDC @ 10A power supply/chargers, two (2) 8-output PTC access power controllers and one (1) 8-output PTC power distribution module. Also featured is a rocker switch bracket with two (2) rocker switches. THW3 backplane accommodates up to six (6) Honeywell 4200 Series or WIN-PAK Series boards and up to two (2) Honeywell PRO22MX8/PW5K1MX8 boards for up to sixteen (16) doors in a single enclosure. THWD2 accommodates additional one (1) Honeywell PRO22MX8/PW5K1MX8 and up to six (6) Honeywell 4200 Series or WIN-PAK Series. Trove simplifies board layout and wire management, reduces installation time and labor costs.
Features
AL1024ULXB2 Power Supply/Charger – 1
- Input
- Voltage: 115VAC, 60Hz, 4.2A max
- Main Fuse: 5A / 250V
- Output
- Voltage: 24VDC (UL 1481)
- Current: 8A continuous supply current with 10A supply current during alarm (UL 1481) 24VDC @ 10A (UL 294)
- Other: Short circuit and thermal overload protection. Filtered and regulated
AL1012ULXB Power Supply/Charger – 2
- Input
- Voltage: 115VAC, 60Hz, 2.6A max
- Main Fuse: 5A / 250V
- Output
- Voltage: 12VDC
- Current: 10A continuos supply current
- Other: Short circuit and thermal overload protection. Filtered and regulated
- Both Power Supplies
- Battery Backup (not included)
- Fuse Rating: 15A @ 32V
- Type: Sealed lead acid or gel type
- Failover: Upon AC loss, instantaneous
- Supervision
- AC Failure: Form “C” contacts
- Battery: Form “C” contacts
- Indicators LED
- Input: 115VAC is present
- DC Output: Powered
- Battery: Discharged or not connected
PD8ULCB Power Distribution Module
- Input
- Voltage: 12VDC from AL1012ULXB
- Outputs
- Voltage: 12VDC
- Eight (8) PTC protected outputs. 2.5A per output max
- Output PTCs: 2.5A
- Indicators (LED)
- Green LED: DC Output
Two (2) ACM8CB Access Power Controllers
- Input
- Voltage: 24VDC from AL1024ULXB2
- Input Fuse: 10A / 250V
- Outputs
- Class 2 power-limited auto-resettable outputs
- Voltage: 24VDC
- Eight (8) 24VDC independently controlled PTC outputs:
a) Fail-Safe and/or Fail-Secure power outputs form “C” Relays rated 28VAC or VDC @ 2.5A.
b) Any combination of the above - Output PTCs: 2.5A
- Indicators (LED)
- Red LEDs: Outputs are triggered (relays energized)
- Green LED: FACP disconnect is triggered
Environmental
- Temperature
- Operating: 0° C to 50° C (32° F to 122° F)
- Storage: – 20° C to 70° C ( – 4° F to 158° F)
- Relative Humidity
- Relative Humidity 85% +/- 5%
- BTU/Hr (approx.):
- 177 BTU/Hr



















Reviews